Gongli Brand PVC Translucent Roof Sheet
Brand | Impression |
---|---|
Color | Milky |
Categories: All, PVC Roof Sheet, Translucent Roof Sheet
Brand | Impression |
---|---|
Color | Milky |
PVC tranlucent roof sheet has some flexibility and impact resistance, making it ideal for protection from extreme weather, flying debris or vandalism.
PVC translucent roof sheet has a light transmittance of 65%-90%, and the light will become softer and less dazzling when it passes through the PVC translucent roof sheet.
PVC tranlucent roof sheet can be cut with simple cutting tools, or can be customized in length from factories or dealers, suitable for DIY enthusiasts to design their own roofs or other pathways.
PVC tranlucent roof sheet provides a certain degree of thermal insulation. PVC tranlucent roof sheet reduces the heat conduction under the light from the material, and provides a higher degree of heat insulation.
PVC tranlucent roof sheet is usually in translucent color, but we can provide customers with color samples to customize the color.
PVC tranlucent roof sheet material is about half the weight of equivalent glass, which means you enjoy lower shipping costs, easier moving and storage, and simplified material handling.
The PVC tranlucent roof sheet can be attached directly to the frame or support structure and the included hardware is designed for quick and easy installation and connection.
Width: 1050mm
Effecived width: 960 mm
Length: Customized
Thickness: 1.5mm, 2.0mm
Application: Large-scale steel structure projects such as sheds, Factories, Warehouses, Markets, Farms, Farms, etc.
Num. | Test Item | Test Method | The Test Condition | Test Result |
1 | Tensile strength | ISO 527-1:2012 & ISO 527 -2:2012 | Testing speed: 50mm/min | 23.1 Mpa |
2 | Flexural strength | ISO 178:2010/Amd.1:2013 Method A | Test speed: 1mm/min | 50.9 Mpa |
3 | Impact Resistance | With reference to GB/T 8814-2004 Section 5.7, Section 6.7 and client’s requirement | -10°C, 1h | Number of specimen failures: 0 |
4 | Vicat Softening Temperature | ISO 306:2013 Method B 50 | Rate of temperature: 50K/h | 77.0°C |
5 | Effects of liquid chemicals | ISO 175:2010 | Temperature: 23°C | No visual change |
ISO 175:2010 | Temperature: 23°C | Visual discoloring, but no other visual change | ||
ISO 175:2010 | Temperature: 23°C | No visual change | ||
6 | Light Ageing Test – Xenon-arc Exposure | ISO 4892-2:2013 cycle 4 & ISO 105-A02:1993/Cor.2:2005 & ASTM D2244– 15a | Exposure period: 1000h | Grey scale: 3 |
7 | Dimensional Stability | With reference to ASTM D1204-14 and client’s requirement | 100℃,60min→23±2℃, 50±5% RH, 60min | Direction of arrow: -0.6% |